D114
D114 Cost-effective · DN25–DN600 Remove D114
What it measures Liquid flow
Typical use Fixed monitoring
Data connection RS485 / 4–20 mA
Installation type Clamp-on
Pipe sizes DN25–DN600
Reviewed specifications
Flow velocity 0.5–5 m/s (1.6–16 ft/s)
Pipe size 25–600 mm (1″–24″)
Accuracy ±2% of reading (0.5–5 m/s)
Repeatability 0.4%
Pipe material Carbon steel, stainless steel, PVC, copper
Communication RS485 with Modbus protocol
Analogue output 4–20 mA, max. load 750 Ω
Power supply 10–36 VDC, 1 A max.
Ambient temperature −10 °C to 50 °C (14 °F to 122 °F)
Transducer temperature 0 °C to 60 °C (32 °F to 140 °F)
Ingress protection Transmitter IP65, transducer IP68
Transducer cable 5 m (16.4 ft) standard