| Specification | |
|---|---|
| What it measures | Liquid flow |
| Typical use | Fixed monitoring |
| Data connection | Pulse / relay |
| Installation type | Clamp-on |
| Pipe sizes | DN20–DN80 |
| Reviewed specifications | |
| Flow velocity | 0.03–5.0 m/s (0.1–16 ft/s) |
| Pipe sizes | DN20, DN25, DN32, DN40, DN50, DN65, DN80 |
| Accuracy | ±2% of reading (0.3–5 m/s) |
| Repeatability | 0.2% |
| Pipe material | Stainless steel, carbon steel, PVC, copper |
| Pulse output | 0–9999 Hz, OCT, adjustable frequency limits |
| Relay output | Max. 1 Hz, 1 A at 125 VAC or 2 A at 30 VDC |
| Power supply | 10–36 VDC, 500 mA max. |
| Ambient temperature | −10 °C to 50 °C (14 °F to 122 °F) |
| Transducer temperature | 0 °C to 60 °C (32 °F to 140 °F) |
| Ingress protection | IP54 |
| Transducer cable | φ5 six-core cable, 2 m (6.6 ft) standard |
No models selected