Specification
P118i
P118i Portable · site surveys Remove P118i
What it measures Liquid flow
Typical use Site surveys
Data connection On-device storage
Installation type Clamp-on
Pipe sizes DN15–DN6000
Reviewed specifications
Flow velocity ±0.01 to ±12 m/s (±0.03 to ±40 ft/s)
Accuracy ±0.5% of measured value
Repeatability 0.15%
Linearity ±0.5%
Pipe size 15–6000 mm (0.6″–240″)
Medium Water
Medium temperature −40 °C to 80 °C (standard)
Output 4–20 mA, max. 750 Ω
Data storage SD card, 2 GB; up to 512 files; interval 1–60 s
Power supply Rechargeable lithium battery, about 10 hours of continuous use
Keypad Tactile keys
Display 3.5-inch TFT colour screen, 320 × 240, backlit
Ambient temperature −10 °C to 50 °C
Humidity 0–99% RH, non-condensing
Transmitter NEMA 13 (IP54)
Transducer Encapsulated, IP68; cable 5 m
Weight Transmitter 1 kg