At a glance

What E3E does, in plain words.

What it measures
Flow and thermal energy
Liquid flow plus supply and return temperatures, to work out heating or cooling energy.
How it installs
Clamp-on
Sensors fit on the outside of the pipe, so the pipe stays closed.
How it connects
PoE / Ethernet
One Ethernet cable carries both power and data.
Works with MeterTube, the pFlow app and cloud platform.
Pipe sizes
DN20–DN80
DN is the nominal pipe size, roughly the inside diameter in millimetres.

Why E3E

E3E in short.

E3E measures water flow and heating or cooling energy from outside the pipe. It uses the transit-time ultrasonic principle with Gentos signal processing and a flow-and-energy algorithm.

Readings are stored in the cloud over its Ethernet connection, so you can view, analyse and query them from a phone or a PC.

  • Power and data over one Ethernet cable (PoE)
  • Works with the MeterTube app and platform
  • Installs without cutting or damaging the pipe
  • No adjustment needed: plug in and measure
  • Colour LCD that rotates through 360°
Where it is used
  • HVAC heating and cooling circuits
  • Energy-saving monitoring
  • Heat balance regulation
  • Heating regulation
  • Air-handling unit (AHU) rooms

How it works

Sound with the flow arrives sooner.

Two sensors on the same side of the pipe take turns sending sound through the water. Sound travelling with the flow arrives slightly sooner than sound travelling against it; the meter turns that time difference into flow, which is why it needs to know your pipe.

  1. Measure the water flow.The ultrasonic sensors read flow through the pipe wall.
  2. Measure two temperatures.Temperature sensors measure the supply and return water.
  3. Calculate thermal energy.The meter combines flow and the temperature difference to give heating or cooling energy.

Pipe & installation

What the meter needs to know about your pipe.

These are set up on the meter after installation. Pipe size and transducer type are decided when ordering.

Pipe & installation guide pipe materials, sizes, setup checklist
E3E clamped on a stainless steel pipe Rendered preview: E3E clamped on a carbon steel pipe Rendered preview: E3E clamped on a galvanized steel pipe Rendered preview: E3E clamped on a ductile iron pipe Rendered preview: E3E clamped on Type K copper tube with green marking Rendered preview: E3E clamped on Type L copper tube with blue marking Rendered preview: E3E clamped on Type M copper tube with red marking Rendered preview: E3E clamped on a PVC pipe Product photo · stainless steel pipe

Stainless steel · 2″ example

A smooth metal surface. Clean the spot, add coupling gel, then clamp the sensor on.

60.3mmacross the outside
2.8mmwall thickness
54.8mmacross the inside

Pipe sizes are names, not measurements: a 2″ pipe is 2.375″ across.

The meter needs Pipe size Wall thickness Material: Stainless steel
Technical details standards, OD / ID, both units
Standard
ASME B36.19 · 2″ Sch 10S
Outside diameter (OD)
2.375″ (60.33 mm)
Wall
0.109″ (2.77 mm)
Inside diameter (ID)
2.157″ (54.79 mm)
Meter parameters
OD · wall · material

This guide shows what a clamp-on meter needs to know about a pipe. It does not mean every model fits every pipe: check the specifications below or ask an engineer.

Specifications

Check the fit before you specify.

The short version is above. These are the specifications published for E3E; values that are still being checked are left out.

Performance

Measurement
Water flow and heating / cooling energy
Flow velocity
0.03–5.0 m/s (0.1–16 ft/s)
Flow accuracy
±2% of reading (0.3–5 m/s)
Energy accuracy
Not specified; the catalog states the flow accuracy only
Repeatability
0.2%
Pipe sizes
DN20, DN25, DN32, DN40, DN50, DN65, DN80
Medium
Water
Pipe material
Carbon steel, stainless steel, PVC, copper

Function

Network
Ethernet with Power over Ethernet (PoE)
Power supply
Power over Ethernet (PoE), IEEE 802.3af/at
Keypad
4 touch keys
Local display
1.44-inch colour LCD, 128 × 128

Physical

Installation
External clamp-on configuration
Ambient temperature
−10 °C to 50 °C (14 °F to 122 °F)
Transducer temperature
0 °C to 60 °C (32 °F to 140 °F)
Temperature sensor
0 °C to 100 °C (32 °F to 212 °F)
Ingress protection
IP54
Cables
PoE waterproof cable 0.5 m (1.6 ft); temperature sensor cable 2 m (6.6 ft)

Need a value that is not listed, or the datasheet for your configuration? Ask an engineer.

What these terms mean
DN
Nominal pipe size, roughly the inside diameter in millimetres (DN50 ≈ 50 mm).
Clamp-on
Sensors strap to the outside of the pipe. No cutting, no shutdown for installation.
PoE
Power over Ethernet: one network cable carries power and data.
LoRaWAN
Long-range, low-power wireless. Readings travel through a gateway to a network server.
Modbus RS485
A wired connection widely used by building and industrial control systems.
4–20 mA
An analogue signal where the current represents the reading.

Documents

Datasheets and manuals.

No reviewed documents are published for E3E yet.

Request the current datasheet or manual →

Compare

A different job may need a different meter.

Compare E3E with others

Is this the right meter for your system?

Share your pipe, liquid temperature and connection requirements with our engineers.

Contact Us